Input Parameters

Results

--
Displacement
in³/rev
--
Flow Rate
GPM
--
Eccentricity
in
--
Vane Tip Speed
ft/min
Note: Vane tip speed should not exceed 4000 ft/min. Balanced vane designs handle higher pressures (up to 3000 psi).

Reference

Eccentricity e = R_ring - R_rotor Displacement ≈ 2π × e × (R_ring + R_rotor) × Width Flow = (Disp × RPM × η_vol) / 231 Tip Speed = 2π × R_ring × RPM / 12