Input Parameters

Results

--
B10 Life
hours
--
B50 (Median) Life
hours
--
Pressure Ratio
--
Life Factor
×
Note: B10 life = 90% of pumps survive this long. Cleanliness is the #1 factor in pump life. ISO 16/14/11 is recommended.

Reference

Pressure Ratio = P_rated / P_operating Life Factor = (P_ratio)³ × Speed Ratio × Cleanliness Factor B10 Life = Base Life × Life Factor B50 ≈ 5 × B10 (median life)