Calculate full bore flow capacity, Cv coefficient, and pressure drop for ball valves
Input Parameters
Pipe Size (in)
Flow Rate (GPM)
Fluid Specific Gravity
Opening Angle (degrees)
Calculate
Results
--
Valve Cv
--
Pressure Drop
PSI
--
Flow Velocity
ft/s
--
K Factor
Reference
Full-bore Cv ≈ 29.85 × D² ΔP = SG × (Q / Cv)² Velocity = Q / (449 × A) K = 890 D⁴ / Cv²